Omega LV800 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Omega LV800. Omega LV800 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
omega.com
For latest product manuals:
omegamanual.info
LV800 SERIES
Capacitance Point Level Sensors
Shop online at
Users Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - User’s Guide

omega.com e-mail: [email protected] latest product manuals:omegamanual.infoLV800 SERIES Capacitance Point Level SensorsShop online atUser’s Guide

Strona 2

SPECIFICATIONSSAFETYPower: 115VAC (±15%); 2.5VA; 50/60Hz / 230VAC (±15%); 2.5VA; 50/60Hz Altitude: 6562 ft (2000 m) maxInstallation Category: IIPollu

Strona 3

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 13 months from date of

Strona 4 - Figure 1

M-4168/0405Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop online at omega.comTEMPERATUREMUThermocouple, R

Strona 5 - ELECTRICAL INSTALLATION

Servicing North America:U.S.A.: One Omega Drive, P.O. Box 4047ISO 9001 Certified Stamford, CT 06907-0047TEL: (203) 359-1660 FAX: (203) 359-7700e-mail:

Strona 6 - CALIBRATION

This manual contains the information necessary to ensure a safe andsuccessful installation. Please read and comply with the section on page9 of this m

Strona 7 - Figure 9

PRE-INSTALLATION CONSIDERATIONS3Choosing a Location: (See Figure 2)1) Material Flow - When selecting a location for the LV800, choose a point in the

Strona 8 - MAINTENANCE

4MECHANICAL INSTALLATIONStandard, Food Grade and Stub Probe Mounting: (See Figures 3 & 4)1) Select a mounting location in accordance with the Pre

Strona 9 - MECHANICALS

5Figure 5Power Input: (See Figure5)The LV800 is designed to accept either 115VAC or 230VAC(factory set). Verify the intended voltage supply is compat

Strona 10 - SPECIFICATIONS

6Delay:A potentiometer is provided for setting the time delay betweenthe time material is "sensed" (Yellow LED on) and the time therelay con

Strona 11 - RETURN REQUESTS/INQUIRIES

TROUBLESHOOTINGMAINTENANCEPROBLEM: Sensor will not sense materialCAUSE/SOLUTION:1) Verify power is applied to the sensor.2) Verify "Sense Adjust.

Strona 12 - Shop online at omega.com

8MECHANICALSStandard ProbeStub ProbeDIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS