2.5 FRONT PANEL LOCKOUT
2.5.1 PUSH BUTTON LOCKOUT
To lock the RESET, MENU and SETPTS buttons, verify that the S3-A jumper is
installed and the S3-E jumper is not installed, then follow these steps:
In the run mode-
1. Press and hold down the RESET button. The meter shows “SP.RS”. Do not
release the RESET button.
2. Press the MENU button and hold RESET button down (3-5 seconds) until the
meter shows “LOCK”.
3. Release both buttons.
To unlock the RESET, MENU and SETPTS buttons, follow these steps:
1. Press and hold down the RESET button. The meter shows “LOCK”. Do not
release the RESET button.
2. Press the MENU button and hold RESET button down (3-5 seconds) until the
meter shows “UN.LK”.
3. Release both buttons.
2.5.2 JUMPER LOCKOUT
To lock all front panel buttons, remove the S3-A jumper (refer to Figure 3-2).
To lock the MENU button only, verify that the S3-B jumper is removed, then install
the S3-A and S3-E jumpers, (refer to Table 3-1).